Skip to main content

Full Steam Ahead: Bronya Climate Shield provides 24% – 42% energy efficiency in Mil-Spec Tests

By: OTC

 

Toronto, May 5, 2021 — OTC PR WIRE — Eco Depot, Inc. (OTC Pink: ECDP), a Nevada company, has engaged National Technical System (NTS) Sci-Lab Material Testing in Kitchener, Ontario, Canada, to conduct Military-Specification (Mil-Spec) Testing to establish third party energy efficiency qualifications for Bronya Climate Shield Paint Coating.

NTS Sci-Lab is a globally recognized ISO 17025 Accredited Laboratory used by Government Agencies and Fortune 500 Companies.

Bronya Canada Group has conducted research and developed a new easy flow consumer-friendly Multi-Purpose Thermal Paint.  It provides increased coverage of 400 Square Feet at a thickness of 1 mm with thermal conductivity of 0.03 W/mk.

The NTS Sci-Lab Material Testing report demonstrates Bronya Climate Shield’s industrial durability and ability to quickly achieve increased energy efficiency on the steam pipes most commonly used in Industrial and Commercial applications.

 

 

This means customers operating steam-based industrial and commercial facilities experience significantly minimized safety risk.”

Note that Bronya Climate Shield can be applied with no disruption to a customer’s operations.

The following NTS test results indicate the effectiveness of 1mm of Bronya Climate Shield in one of many applications to increase energy efficiency in multiple consumer markets.

Summary of Methodology:

Tests were conducted on three mild steel 1” inch diameter pipes, most commonly used for steam pipes, to demonstrate Bronya Climate Shield’s efficacy at different temperatures.  All samples were individually exposed to 25 °C or 77 °F external chamber temperature while internal temperatures ramped to 50 °C or 122 °F, 100 °C or 212 °F, 150 °C or 302 °F and 200 °C or 392 °F.  All calculations taken on each sample for BTU, Joules, Averages, Difference & Difference (%) are based on Celsius rounded values.

Summary of Results & Conclusions:

  • Insulated pipes showed a noticeable difference between the internal temperature of the pipes and the measured external temperatures.
  • The internal and external difference was greater for all measurements taken on the insulated pipe samples when directly compared to an uninsulated pipe.

There was no noticeable difference in the appearance of the coating after all Temperature Testing.  Refer to Tables 1 to 8 of the report for detailed temperature difference results, which averaged between 24.38 % and 42.98% of energy savings

Table 1: 577726-1i to 1iii 50±3°C Internal Temperature Testing Results Note 2

 

IDStyleInternal Temp. (°C) / (BTU) / (Joules)External Temp. (°C) / (BTU) / (Joules)Internal Vs. External Difference (°C)/ (BTU) / (Joules)
1iCoated Pipe48.81 / 87.86 / 92695.1036.91 / 66.44 / 70095.8011.90 / 21.42 / 22599.30
1iiCoated Pipe49.94 / 89.89 / 94841.0835.84 / 64.51 / 68063.7614.10 / 25.38 / 26777.32
1iiiCoated Pipe51.27 / 92.29 / 97366.8836.45 / 65.61 / 69222.2114.82 / 26.68 / 28144.67
Average:50.01 / 90.02 / 94974.0236.40 / 65.52 / 69127.2613.61 / 24.50 / 25846.76

Table 2: 577726-2i 50±3°C Internal Temperature Testing Results Note 2

 

IDStyleInternal Temp. (°C) / (BTU) / (Joules)External Temp. (°C) / (BTU) / (Joules)Internal Vs. External Difference (°C)/ (BTU) / (Joules)
2iUncoated Pipe50.42 / 90.76 / 95752.6542.15 / 75.87 / 80047.098.27 / 14.89 / 15705.56

Table 3: 577726-1i to 1iii 100±3°C Internal Temperature Testing Results Note 2

 

IDStyleInternal Temp. (°C) / (BTU) / (Joules)External Temp. (°C) / (BTU) / (Joules)Internal Vs. External Difference (°C)/ (BTU) / (Joules)
1iCoated Pipe97.91 / 176.24 / 185940.9370.60 / 127.08 / 134076.5027.31 / 49.16 / 51864.44
1iiCoated Pipe98.59 / 177.46 / 187232.3261.73 / 111.11 / 117231.4836.87 / 66.37 / 70019.84
1iiiCoated Pipe99.97 / 179.95 / 189853.0865.09 / 117.16 / 123612.4534.88 / 62.78 / 66240.63
Average:98.82 / 177.88 / 187669.1265.81 / 118.46 / 124979.8133.02 / 59.44 / 62708.30

 Table 4: 577726-2i 100±3°C Internal Temperature Testing Results Note 2

 

IDStyleInternal Temp. (°C) / (BTU) / (Joules)External Temp. (°C) / (BTU) / (Joules)Internal Vs. External Difference (°C)/ (BTU) / (Joules)
2iUncoated Pipe100.85 / 181.53 / 191524.2980.42 / 144.76 / 152725.6720.43 / 36.77 / 38798.62

Table 5: 577726-1i to 1iii 150±3°C Internal Temperature Testing Results Note 3

 

IDStyleInternal Temp. (°C) / (BTU) / (Joules)External Temp. (°C) / (BTU) / (Joules)Internal Vs. External Difference (°C)/ (BTU) / (Joules)
1iCoated Pipe149.37 / 268.87 / 283668.65103.67 / 186.61 / 196879.7545.68 / 82.22 / 86750.91
1iiCoated Pipe148.86 / 267.95 / 282700.1192.86 / 167.15 / 176350.4856.00 / 100.80 / 106349.63
1iiiCoated Pipe152.74 / 274.93 / 290068.6291.32 / 164.38 / 173425.8661.42 / 110.56 / 116642.76
Average:150.32 / 270.58 / 285472.7995.95 / 172.71 / 182218.7054.37 / 97.87 / 103254.10

 Table 6: 577726-2i 150±3°C Internal Temperature Testing Results Note 3

 

IDStyleInternal Temp. (°C) / (BTU) / (Joules)External Temp. (°C) / (BTU) / (Joules)Internal Vs. External Difference (°C)/ (BTU) / (Joules)
2iUncoated Pipe149.30 / 268.74 / 283535.71114.90 / 206.82 / 218206.6534.40 / 61.92 / 65329.06

 Table 7: 577726-1i to 1iii 200±3°C Internal Temperature Testing Results Note 3

 

IDStyleInternal Temp. (°C) / (BTU) / (Joules)External Temp. (°C) / (BTU) / (Joules)Internal Vs. External Difference (°C)/ (BTU) / (Joules)
1iCoated Pipe200.16 / 360.29 / 380123.96144.41 / 259.94 / 274249.1155.75 / 100.35 / 105874.86
1iiCoated Pipe199.29 / 358.72 / 378471.75113.64 / 204.55 / 215813.7985.66 / 154.19 / 162676.95
1iiiCoated Pipe200.78 / 361.40 / 381301.41118.87 / 213.97 / 225746.0881.91 / 147.44 / 155555.33
Average:200.08 / 360.14 / 379972.04125.64 / 226.15 / 238602.9974.44 / 133.99 / 141369.04

Table 8: 577726-2i 200±3°C Internal Temperature Testing Results Note 3

 

IDStyleInternal Temp. (°C) / (BTU) / (Joules)External Temp. (°C) / (BTU) / (Joules)Internal Vs. External Difference (°C)/ (BTU) / (Joules)
2iUncoated Pipe198.33 / 356.99 / 376648.61154.86 / 278.75 / 294094.7143.47 / 78.25 / 82553.90

 

Note: A copy of the full NTS Sci-Lab report is available in Eco Depot, Inc. (ECDP) Supplementary Filings, and also available by request at Eco Depot corporate.

Product Information

Bronya Climate Shield™ is multi-purpose liquid insulation that can be applied on any surface, both indoors and outdoors, at temperatures of –60 °C up to +200 °C. Bronya Climate Shield is a cost-effective Do-It-Yourself (DIY) product with thermal conductivity of 0,03 W/mk, proven to reduce energy costs by up to 40% and labor costs by 70%. Moreover, this excellent quality product provides insulation lasting from 10 to 30 years, depending on the application.

Bronya’s product line also includes a thermal waterproof, fire-retardant and anti-corrosion liquid insulating paint coating. Bronya Climate Shield can provide its end-users with an easy-to-use, safe, and cost-effective liquid thermal insulation paint product line that drastically improves the thermal efficiency in building, transportation, and industrial sectors.

Note: A copy of the full report is available in Eco Depot, Inc. (ECDP) Supplementary Filings.

ABOUT NATIONAL TECHNICAL SYSTEM (NTS) Sci-Lab Material Testing Labs.

Established in 1961, NTS is celebrating its 60th anniversary in 2021. Over the last 60 years, NTS has worked on the world’s most complex engineering projects. Whether it’s Apollo 11, NASA’s Artemis program, the ITER nuclear reactor, or the latest EV projects, NTS continues to push the boundaries of testing innovation. With headquarters in California and 28 labs in North America, NTS provides customers with best-in-class testing services to serve a wide range of industries, including space, defense, automotive, energy, electronics, telecommunications, medical, IoT, industrial, and aviation. (https://www.nts.com)

ABOUT ECO DEPOT

Eco Depot, Inc. acquires, manages, and develops eco-friendly real estate assets and consumer brand products. Their focus is to provide investments, funding, and support for acquisitions, start-ups, entrepreneurs, and green companies dedicated to protecting the environment. Eco Depot is a development stage distributor of eco-friendly consumer brand products and is publicly traded Over the Counter at OTCMKTS: ECDP.

ABOUT BRONYA CANADA GROUP

Bronya Coatings Group, Inc. (“the Company”) is based in Montreal and intends to commercialize a Multi-Purpose liquid thermal insulation paint Bronya Climate Shield product line in North America. The Company’s mission is to establish third-party production facilities on a global scale to reduce the costs associated with the business’ supply chain. The Company also has established relationships with major home improvement stores on a worldwide basis.

ABOUT BRONYA CLIMATE SHIELD™

Bronya Climate Shield™ increases energy efficiency, energy savings and reduces carbon emissions through energy conservation. Product website: www.bronyaclimateshield.com

Contact:

Eco-Depot Inc

2300 West Sahara Avenue

Suite 800

Las Vegas, NV 89102

Website: www.ECDP.co

Tel: 1 (800) 323-7006

info@ecdp.co

PRODUCT INQUIRIES:

+1-(844)-427-6692
info@bronyaclimateshield.com

Disclaimer:

Certain statements contained in this release may constitute forward-looking statements within the meaning of the Private Securities Litigation Reform Act of 1995 and other U.S. Federal securities laws. Such statements include but are not limited to statements identified by words such as “believes,” “expects,” “anticipates,” “estimates,” “intends,” “plans,” “targets,” “projects” and similar expressions. The statements in this release are based upon the current beliefs and expectations of our Company’s management and are subject to significant risks and uncertainties. Actual results may differ from those outlined in the forward-looking statements. Numerous factors could cause or contribute to such differences, including, but not limited to, results of clinical trials and other studies, the challenges inherent in new product development initiatives, the effect of any competitive products, our ability to license and protect our intellectual property, our ability to raise additional capital in the future that is necessary to maintain our business, changes in government policy and regulation, potential litigation by or against us, any governmental review of our products or practices, as well as other risks discussed from time to time in our filings with OTC Markets including, without limitation, our latest Annual Report filed March 30th, 2021. We undertake no duty to update any forward-looking statement or any information contained in this press release or other public disclosures at any time. Finally, the investing public is reminded that the only announcements or information about Bronya Climate Shield or Eco Depot Inc. which are condoned by the Company, must emanate from the Company itself and bear our name as its source.

 

 

 

 

 

Full Steam Ahead: Bronya Climate Shield provides 24% – 42% energy efficiency in Mil-Spec Tests
Data & News supplied by www.cloudquote.io
Stock quotes supplied by Barchart
Quotes delayed at least 20 minutes.
By accessing this page, you agree to the following